Product Navigation

High temperature high humidity reverse bias burn-in test system(H3TRB2000)

The system can conduct high temperature and high humidity (double 85) burn-in test. During the burn-in process, it can monitor the leakage current status and voltage status of the tested component in real time, (record and export the burn-in test data as required).

Function

  • nA level leakage current detection accuracy
  • 30s full station data refresh of the machine
  • Unique high-voltage suppression circuit, instantaneous breakdown of components, without affecting burn-in process of other stations
  • Customizable independent control function of burn-in voltage of work station to realize single work station burn-in over limit rejection
  • Adequate human safety considerations for operators

Product Features

Test temperature zone

1

Test temperature

RT+10~150℃

Test humidity

10%rh~98%rh

Test zone

16(8/16 zoneoptional)

Stations per zone

80 (typical)

Burn-in voltage

0~±2000V

Voltage detection accuracy

±(1%+2LSB)

Current detection

10nA~50mA

Current detection accuracy

±(1%+10nA)

Machine power supply

Three-phase AC380±38V

Maximum power

10KW  (typical)

Total weight

1000KG  (typical)

Dimensions of machine

1650mm(W)×1750mm(D)×1950mm(H)


Applicable standards

GJB128 MIL-STD-750D AEC-Q101 JESD22-A101

Applicable components

For MOS FET, diode, triode, IGBT module, PIM module, thyristor, etc