High temperature static burn-in test system for microwave tubes(MFS2004)
The system is configured with 12 independent test zones, each of which has 4-way component burn-in stations, and the whole machine has 48 component burn-in stations. The 12 test zones can be independently or simultaneously controlled, monitored, recorded, and communicated through the upper computer. Each station can independently control the shell temperature of the tested component, and the detection accuracy is 1% ± 2 ℃. Real time monitoring and recording of various parameters of the component during burn-in process, and using the technologically advanced adjustable voltage stabilized high-power secondary power supply.
Function
- Real-time monitor of the current and voltage status of the component, and automatic adjust burn-in the current of the component
- Can independently control the shell temperature of the component with an accuracy of 1%±2℃
- Can be adapted to microwave power components with different packaging and power requirements
Product Features
Test temperature zone | 12 |
Test temperature | 70~200℃ |
Test zone | 12 |
Drain voltage control | 0.01~60V |
Drain voltage control accuracy | ±(1%+0.1V) |
Grid voltage control | -10~10V |
Grid voltage control accuracy | ±(1%+0.01V) |
Leakage current detection | 0~5A |
Leakage current detection accuracy | ±(1%+1mA) |
Grid current detection | 0~50mA |
Detection accuracyof grid current | ±(1%+0.01mA) |
Shell temperature fluctuation | ±1℃ |
Shell temperature detection accuracy ±(1%+2℃) | ±(1%+2℃) |
Power supply | 0~60V/40A (Optional 12 channels) |
Machine power supply | Three-phase AC380V±38V |
Maximum power | 25KW (typical) |
Total weight | 1000KG(typical) |
Dimensions of machine | 1800mm(W)×1300mm(D)×2000mm(H) |
Applicable standards
GJB128 MIL-STD-750 MIL-M-19500
Applicable components
For GaN,GaAs and other microwave tubes