Wafer-level reliability test system(CWBS1000)

The system is suitable for electrical reliability test for controllable high-temperature for 6/8-inch wafer-level devices based on JEDEC reliability test standard; It provides high-precision and high-voltage output, and saves records high-precision current, controllable temperature and other parameters, and according to the recorded test data, export experiment tables and MAP diagrams in multiple formats.

Function

  • Customized high-temperature adjustment semi-automatic probe station, supporting ≤5 wafers simultaneous burn-in test
  • Support the independent protection function of each wafer die, and control the over-current and over-voltage beyond the limit
  • Support nitrogen protection to prevent wafer oxidation, and support overvoltage protection when filling
  • Support to change the Burn-in Board or probe card to different package devices for test
  • Support wafer mounting contact spot detection, real-time temperature and pressure detection
  • Support HTGB, HTRB and other burn-in test functions, Vth/IDS/IGS and other parameters of automatic testing and data analysis
  • Support built-in wafer layout MAP configuration, real-time display of data and query of historical data
  • Support access to the centralized control station (smart core protection cloud) system, customized docking with the MES system

Product Features

Test temperature zone

1 (Support customization ≤5)

Test temperature

RT-200℃

Applicable products

GaN/SiC and other 6-inch and 8-inch wafers

Multi-station parallel test

1 (Support customization ≤5)

Temperature overshoot

<2℃

Grid voltage range (accuracy)

±60V(0.1%±10mV)

Grid current range (accuracy)

HTGB: 0.1nA~1uA (1%±100pA)
Vth: 0~20mA (0.1%±20uA)

Source voltage range (accuracy)

50~2000V(0.5%*Vmax±1V)

Source current range (accuracy)

1nA~1mA(1%±5nA)

Voltage and current overshoot

HTRB overshoot<2%,HTGB overshoot<200mV

Methods of communication

TCP network/485 serial port

Operating system

Windows 7 and above

MES system interface

Customize and integrate with third-party systems and data

Total weight

850Kg

Dimensions of machine

2050mm(w)x1400mm(D)x1750mm(H)

Single-chamber size

1920mm(w)x1250mm(D)x300mm(H)


Applicable standards

AEC-Q101 JEP183 IEC60749-23 JESD22-A108F

Applicable components

For high-temperature and high-voltage reliability test of wafers such as GaN/SiC, and automatic test and data analysis of Vth, Igs, Ids and other parameters.